GPS tracker digital inputs are usually the last thing a buyer reads on a spec sheet and the first thing an installer asks about. A tanker fleet wants to know when the pump runs, a cold chain manager wants cargo temperature at every stop, and a security team wants drivers to raise an alarm without a phone. None of that comes from GPS. It comes from the wires and ports around the tracker.
This article explains what each type of tracker input and output does in a fleet and how to decide what goes where. It covers digital, analog and AD inputs, pulse counters, serial ports, outputs and relays, an input planning sequence, and common mistakes, using the Tracom ST100 as the reference.
What tracker inputs and outputs do
Inputs tell a tracker what is happening on the vehicle: whether the ignition is on, a door is open, how much fuel is in the tank, or which driver presented a key. Outputs let it act on a vehicle circuit, usually through a relay, and ports connect accessories that send richer data.
The value of inputs is context. A stop with the PTO engaged means work is happening; the same stop with the ignition off means the vehicle is parked. Without inputs, both look identical on the map.
The ST100 interface set
The ST100’s published interfaces are listed below. The typical uses in the last column describe common fleet practice, not a fixed assignment on the device.
| Interface | ST100 count | Typical fleet use |
|---|---|---|
| Digital inputs | 12 | Ignition, PTO, doors, seat belt, panic button |
| Analog inputs | 4 | Signals that vary, such as sensor voltage |
| AD inputs | 5 | Additional measured signals |
| Digital outputs | 2 | Relays for buzzers, lights, or other circuits |
| Pulse counters | 2 | Flow meters and rotation sensors |
| RS232 ports | 5 | Serial sensors and accessories |
| USB, UART, 1-wire | Included | Accessory and identification connections |
What the device does not decide
A digital input changing state does not automatically determine what happened in the field. A door input that goes active tells the tracker that a circuit closed. It does not tell anyone whether the door was opened by the driver, a customer, or a thief. Tracom supplies the GPS device, local rule logic, event data, and configuration layer. The fleet or its connected business software assigns the operational meaning and response.

The tracking device behind every record
- GPS, GLONASS, SBAS, QZSS and AGPS positioning
- Location accuracy within a 2-meter radius
- 2G/3G/4G SIM support
- 12 digital, 4 analog and 5 AD inputs, 2 digital outputs
- 5 RS232 ports, USB, UART, 1-Wire and OBD II CAN
Digital inputs for status signals
A digital input reads one of two states: on or off. That makes it the right input for anything that behaves like a switch. The ST100 has 12, enough for core vehicle signals plus job-specific ones.

Ignition, PTO, door and seat belt signals
The ignition signal separates engine-on time from parked time, so trip and idle reports depend on it. Ignition, engine hours, PTO, door and other status signals can be wired to a digital input, agreed with the Tracom team for each vehicle type. The ST100 reports seat belt violations and can trigger voice alerts for them, and the seat belt signal source is agreed during the same wiring plan.
PTO deserves attention on trucks with mounted equipment, such as mixer drums, tipper bodies, cranes, or vacuum pumps. A PTO input separates productive engine time from idling, which changes how fuel and utilization reports are read.
Panic button inputs
In general, a panic button is a switch placed within the driver’s reach, and switches are a natural fit for digital inputs. The ST100 supports a panic alert, and Tracom supplies panic buttons as an accessory. Type, placement, and fit for each vehicle are confirmed with the Tracom team. Placement and response planning are covered in the guide to the vehicle panic button.
Naming inputs so reports make sense
An input called “DIN 3” means nothing to a supervisor. Give each input a business name, such as “Rear door” or “PTO pump”, and keep it identical across vehicles of the same type so reports can compare them.
Read also: Truck Tracking Device: Hardware, Rules and Data for Truck Fleets
Analog, AD inputs and pulse counters
Some signals are not on or off. A fuel level or a temperature moves across a range, and other signals arrive as pulses that must be counted rather than measured.

Analog and AD inputs for measured values
Analog inputs read a signal that varies, usually a voltage that changes with the measured quantity. The ST100 lists four analog inputs and five AD inputs separately. Which input a particular sensor should use, and how its signal is converted into liters or degrees in reports, is part of the wiring plan agreed with the Tracom team.
Tracom supplies fuel level sensors, and their type and fit for each tank are confirmed with the Tracom team. The differences between sensor technologies are explained in the article on fuel level sensor types.
Pulse counters for flow and rotation
A pulse counter adds up electrical pulses from a device that produces one pulse per unit, such as a flow meter on a fuel dispensing line or a rotation sensor on a drum. The ST100 has two pulse counters, and the specific meter or sensor is validated with the Tracom team before rollout.
Serial ports, 1-wire and USB connections
Serial interfaces carry structured data, so one accessory can send several values, an identifier, or a status message. The ST100 provides five RS232 ports, plus USB, UART, and a 1-wire interface.

RS232 for sensors and accessories
RS232 is a long-established serial standard for point-to-point connections. In the wider market, digital fuel sensors, some temperature sensors, and in-cab accessories use it because they send more than one value. Five ports leave room for several accessories, such as a fuel sensor on each tank. Which accessory connects to which port on the ST100 is confirmed with the Tracom team.
1-wire for identification and temperature
1-wire is a bus that carries data over a single signal line. In the industry it is often used for driver identification keys and for some temperature probes. Tracom supplies driver key readers and temperature sensors; the interface each one uses and its fit with the ST100 are confirmed with the Tracom team. Driver identification options are explained in the article on driver identification, and reefer applications in the guide to the reefer temperature sensor.
USB and UART
USB and UART are general serial interfaces whose role depends on the accessories chosen. Tracom also supplies the M1N MDVR for fleets that need video next to tracking data; how it works alongside the ST100 is confirmed with the Tracom team.
Digital outputs and relays
A digital output switches a low-power signal. In fleet installations it usually drives a relay, which controls a circuit such as a buzzer, a warning light, or another vehicle function.

What two outputs can control
The ST100 has two digital outputs. Fleets often reserve them for functions that need a local response, such as an external warning device in a noisy cab. What each output controls, and how the relay is installed, is agreed with the Tracom team and documented per vehicle type.
Immobilization and authorized drivers
The ST100 supports up to 1,000 driver access keys and an immobilization function, so only authorized drivers with access keys can operate the vehicle. Do not assume immobilization uses the two general-purpose outputs described above; its wiring is agreed with the Tracom team for each vehicle. The engine cut-off topic is covered in the article on the GPS tracker with engine cut-off.
Read also: GPS Fleet Tracking Device: How It Works
Steps to plan your tracker input map
An input map lists every signal, its interface, its business name, and the event it creates. Writing it before installation prevents most field problems.
- List the questions each vehicle group must answer, such as engine-on time, PTO use, door openings, fuel level, or cargo temperature.
- Separate signals into on/off states, measured values, counted pulses, and accessories that send structured data.
- Assign each signal to a digital input, analog or AD input, pulse counter, or serial port, and agree the assignment with the Tracom team.
- Choose the accessories Tracom supplies for the job, such as driver key readers, panic buttons, fuel level sensors, or temperature sensors, and confirm type and fit for each vehicle.
- Give every input a business name and keep it identical across vehicles of the same type.
- Define the events and voice alerts each input should produce in the XML configuration, then push it to a pilot group through the SCMS portal.
- Test every input on real vehicles during the pilot, comparing the reported state with what the installer sees on the vehicle.
- Approve the map and roll it out by vehicle group, with one documented version per group.
Share your vehicle types, the signals each group needs, and the accessories you are considering, and talk to a Tracom specialist about an input map for your fleet.
Common input and output mistakes
Unreliable sensor data usually comes from planning and installation choices.
| Failure | Operational consequence |
|---|---|
| Ignition taken from the wrong source | Trips and idle time are split or merged incorrectly |
| Different input numbers for the same signal | Reports cannot compare vehicles of the same type |
| Generic input names in the configuration | Supervisors cannot read events without asking the installer |
| Sensor chosen before checking fit | The accessory cannot be read and must be replaced |
| No pilot test of each input | Wrong signals reach reports for months before anyone notices |
| Outputs wired without documentation | Service teams cannot trace what each relay controls |
Most of these failures start when the input map lives in an installer’s notebook instead of the configuration. The telematics hardware guide explains how inputs fit into the wider hardware evaluation.
How Tracom supports sensor and accessory connections
At Tracom, we supply the Tracom ST100 with enough inputs and ports for fleets that need more than location. The interface set and related capabilities are:
- Twelve digital inputs, four analog inputs, five AD inputs, two digital outputs, and two pulse counters.
- Five RS232 ports, USB, UART, a 1-wire interface, and an OBD-II CAN interface.
- Second-by-second recording of sensor inputs, with up to one week of onboard storage when the network drops.
- Panic alert, seat belt violation events, and driver voice alerts.
- Up to 1,000 driver access keys, with immobilization so only authorized drivers operate the vehicle.
- Central configuration through the SCMS portal, using XML files with hundreds of customizable events, OTA updates, and SMS commands for selected parameters.
We also supply the accessories that use these inputs: driver key readers, panic buttons, fuel level sensors, and temperature sensors, plus the M1N MDVR. Type and fit for each accessory are confirmed with our team, and the input assignment for your vehicles should be confirmed during solution design. Vehicle data read through the CAN interface is covered in the guide to the CAN bus GPS tracker. See the features page and the services page for capabilities and remote configuration. Request a device recommendation for your fleet or your customers’ fleets.
Conclusion
GPS tracker digital inputs, analog inputs, and serial ports turn a location device into a source of operational facts: engine time, PTO use, fuel level, cargo temperature, and driver identity. The value depends on a clear map of what each input means and a pilot that proves each signal.
Tracom provides the ST100, the accessories that connect to it, and the configuration tools that keep input names and events consistent across a fleet. Share your vehicle types, required signals, and accessory list, and talk to a Tracom specialist to receive a practical input and accessory plan.
Frequently asked questions
How many inputs and outputs does the ST100 have?
The ST100 has 12 digital inputs, 4 analog inputs, 5 AD inputs, 2 digital outputs, and 2 pulse counters. It also provides five RS232 ports, USB, UART, a 1-wire interface, and an OBD-II CAN interface. The assignment of each signal to an interface is agreed with the Tracom team for each vehicle type.
What is the difference between a digital and an analog input?
A digital input reads two states, on or off, so it suits switches such as ignition, doors, PTO, or a panic button. An analog input reads a value that varies across a range, such as a sensor voltage that changes with fuel level or temperature. Each sensor’s input type is agreed in the wiring plan.
Can I connect any fuel or temperature sensor to the ST100?
No. Sensors differ in output type, interface, and protocol, so each model must be checked before purchase. Tracom supplies fuel level sensors and temperature sensors, and their type and fit for your tanks and cargo areas are confirmed with the Tracom team, then tested on real vehicles during the pilot.
What are digital outputs used for in a fleet?
A digital output lets the tracker switch a circuit, usually through a relay. Fleets use outputs for functions that need a local response, such as an external warning device. The ST100 has two digital outputs, and what each one controls is agreed with the Tracom team and documented per vehicle type.
Does Tracom decide what each input means for our operation?
No. Tracom supplies the ST100, the accessories, the input configuration, and the event data. Your team decides what an input event means operationally, for example whether a door opening outside a site needs action, and who responds. The connected tracking platform or your business software applies those decisions in reports and workflows.
Choose the right tracker for every vehicle
Tell us your vehicle types and what you need to monitor. A Tracom device specialist will reply by email with a recommended ST100 setup and accessories.
Usually replies within one business day • No sales spam
Your details are used only to respond to your request. Privacy Policy