Compliance · Free finder

Reefer sensor plan: probes, door contacts and humidity per body

Enter the body length, the compartments, the doors and the logging interval. Get the temperature probes, door contacts and humidity sensor the reefer needs, then check what your vehicle has today. Product ranges stay with the cold-chain checker.

Runs in your browserEditable sensor defaultsSource checked 3 Nov 2026
Source and date checked

The rows here are notes taken from the SFDA document General Requirements for Food Transport. Last checked against the official SFDA PDF: 3 Nov 2026. The Arabic original prevails over the English translation, and rules change, so open the document again before an audit. This finder is not an SFDA decision and does not say that any vehicle or device is approved.

Choose the main product. For a mixed load, check each product and keep to the strictest range.

Cold body
m

Inside length of the cold body.

Separate temperature zones in one body.

doors

Doors that open into the cold body: rear, side or curtain.

m

Tracom suggestion, typical value. Replace it with your own practice or your customer rule.

min

Tracom suggestion, typical value. Shorter intervals catch short door openings.

Typical value. Replace with your device datasheet value.

How the plan is worked out
probes per compartment = round up (compartment length / length one probe covers) temperature probes = probes per compartment × compartments door contacts = one per door humidity probes = one per compartment readings per day = (temperature + humidity probes) × floor(1440 / interval)Door contacts log events, so they are not counted in the readings per day.
Suggested sensorsTracom suggestion

Keep the check in the vehicle file

Report with the requirement rows, the sensor plan and the gaps.

Reefer requirement report

Get the report for your quality file

  • Product and range on file, with the source
  • The source note and the check date
  • Suggested probes, door contacts and interval
  • Gaps found on your vehicle
  • Next steps and method

What does the SFDA reefer requirement finder show?

A reefer inspection comes down to a few questions. What range does this product need? Is there a thermometer I can read from outside? Is the temperature recorded? Can you show the log? This finder puts those questions in one place and ties each one to a sensor.

It works in three steps:

  • Requirements: the range for your product and the monitoring points, each with its source.
  • Sensor plan: how many temperature probes, door contacts and humidity probes a body of your size needs, and how often to log.
  • My vehicle: your setup against the list, with the gaps marked.

How is the sensor plan worked out?

probes per compartment = round up (compartment length / length one probe covers) temperature probes = probes per compartment × compartments door contacts = one per door humidity probes = one per compartment readings per day = (temperature + humidity probes) × floor(1440 / interval)The two defaults below are editable in the tool.
Tracom suggestion defaults (typical values)
ParameterValue
Length one probe covers6 mtypical
Logging interval5 mintypical

Typical value. Replace with your device datasheet value.

These are Tracom suggestions, not SFDA figures. A longer body needs more probes because the door end and the unit end can read differently. A shorter interval catches short door openings but stores more readings.

What do you need to enter?

  • The main product on the vehicle. For a mixed load, check each product and keep to the strictest range.
  • The inside length of the cold body, the number of compartments and the number of doors.
  • Optional: change the length one probe covers and the logging interval to match your procedure.
  • Your current setup: probes, humidity probes, door contacts, interval, outside thermometer and recording.

Worked example: a 12 m reefer with two doors

A body is 12 m long with one compartment and two doors. It carries chilled dairy. The defaults are one probe per 6 m and a 5 minute interval.

  • Probes: 12 / 6 = 2, so 2 temperature probes.
  • Door contacts: one per door, so 2. Humidity probes: one per compartment, so 1.
  • Readings per day: 1440 / 5 = 288 per probe. With 2 temperature probes and 1 humidity probe that is 3 x 288 = 864 readings per day.

With the example values in My vehicle (1 probe, no humidity probe, 1 door contact, a 15 minute interval and an unsure answer on the outside thermometer) one point out of six is in place, so the result is Points to check.

What mistakes do reefer operators make?

  • Using one probe for the whole body. A probe near the cooling unit can read cold while the door end is warm.
  • Skipping the door contact. Without it, a warm spike in the log has no explanation.
  • Logging too rarely. Readings every 30 minutes can miss a 10 minute door opening.
  • Reading the set point as the product temperature. The set point is what the unit was asked to hold.
  • Treating a copied table as law. Open the current SFDA document and check the line.

Assumptions and limits

The requirement rows are notes from the SFDA document, last checked against the official PDF on 3 Nov 2026. Sensor counts and the logging interval are Tracom suggestions with typical defaults. The finder does not read sensors, check calibration or judge product safety. It is not an SFDA inspection or decision, and it does not say that any vehicle or device is approved. Verify against the current official text.

Related Tracom solution

Record the temperature where the product sits

Tracom builds trackers, MDVRs and sensors, including temperature sensors. Send your body length, zones, doors and logging interval and we will confirm which Tracom sensors and device settings fit.

  • Temperature sensors for each zone of the cold body.
  • Door contacts (where the device model has an input for them) so each opening shows in the log next to the reading.
  • Configuration files to set the logging interval to your procedure.
  • Over-the-air updates to change settings without a workshop visit.
Questions

Common questions about SFDA reefer requirements

Need help matching sensors to your body? Contact Tracom.

What temperature does SFDA ask for chilled and frozen food in transport?

In our notes from the SFDA General Requirements for Food Transport: 1.5 to 10 °C for refrigerated containers depending on the product, −18 °C or colder for frozen food, 5 °C or colder for chilled dairy, meat and poultry, and 0 °C for fresh fish and crustaceans. We have not confirmed the current text, so check the document before you rely on these.

Does SFDA say how many sensors a reefer needs?

Not in our notes. They name a thermometer readable from outside the load space, continuous temperature recording and tools to measure humidity. The probe count, door contacts and logging interval here are Tracom suggestions with typical defaults that you can change.

Does the document name a logger type or a record-keeping period?

No, not in our notes. Ask your customer or your quality team how long they want records kept.

Is humidity limited to a number?

No number is recorded in our notes. They list tools to measure humidity. Check the document if your product needs a limit.

Does this tool cover medicines?

No. Medicines follow separate SFDA guidance on storage and distribution. Use the manufacturer label conditions.

Does a result with no gaps mean my vehicle is approved?

No. The finder compares your answers with a list of notes. It is not an SFDA inspection, and Tracom does not approve vehicles or claim any approval for its devices. Confirm with SFDA and your quality team.

Plan your reefer fit-out

Bring the sensor plan to the workshop

Send us the report from this page: product, body length, zones and doors. We will reply with the sensors and settings that match.

Get the report

Enter your details and we will email you the file.

Use your real name so the file arrives addressed to you. Don't worry, we won't flood you with emails or calls.